Home | Grouts & Grout Pumps ...
MASTERFLOW 870 Grout
Masterflow 870 is a non shrink, natural aggregate
precision grout with excellent high early and ultimate
strengths. It is specially formulated to provide extended
working time even at high ambient temperatures when
mixed and placed at any recommended consistency.
Masterflow 870 is normally placed at a flowable consistency
to completely fill voids between 10mm and 100mm.
Thicknesses greater than 100mm are possible with the
addition of aggregate.
All precision, non shrink grouting applications with clearances of 10mm or more including:
- Critical equipment baseplates, soleplates and columns.
- Precast wall panels, beams, columns, structural building members and curtain walls.
- Patching poured in place concrete structures e.g. honeycombing, using preplaced aggregate techniques.
- Underpinning.
- Concrete repair applications where a form and pour material is required.
- Applications requiring high early compressive strengths and high ultimate compressive strengths.
FEATURES AND BENEFITS
- High early strength - ensures rapid commissioning of
new equipment and structures.
- High ultimate strength - ensures permanence of the
installation under static & moderate repetitive loads.
- Flowable long life grout - easy to grout intricate spaces
normally inaccessible by conventional grouting
technique.
- Extended working time - facilitates grouting of large or
difficult placements in a single pour, often without the
use of a pump.
- Economical - greater volumes of grout can be mixed
and handled with less labour.
- Dense, non-shrink grout - hardens free of bleeding,
settlement and drying shrinkage, ensuring tight contact
with all grouted surfaces.
- Easy to use - requires no special mixing equipment, it
can be mixed in a standard concrete mixer or in a pail
using a grout stirrer.
- No added chloride.
- Strict quality control - ensures reliable and consistent
product performance.
- Compliance with codes - Meets the non-shrink
requirements of ASTM C1090 and CRD-C 621, Corps
of Engineers Specification for Non Shrink Grout;
provides complete non shrink performance when tested
in accordance with simulated Bedplate Technique;
tested to the requirements of AS1478.2 "Methods of
sampling and testing admixtures for concrete, mortar
and grout".